SL209PI-T0121 Proportional-Integral Controller Abstract: SL209PI-T0121 is one has two control loop independent intelligence general controller, each control loop can be applied to two PI controls and four switch controls; SL209PI-T0121 has the 1NTC thermistor sensor (internal) inputs,1 analog input; SL209PI-T0121 also has two digital outputs and one analog output.These outputs needs through the software programming to choose specific control loop.SL209PI-T0121 has the formidable control function,users only need to change the parameter setting ,and the control requirements can be achieved ,without the need for other tools or software programming and so on. Product features: * The temperature control is suitable for 2 controls, 4 control HVAC systems. * -H version;Humidification humidity control, dehumidification and humidity sensor integration. * Any general PID control analog input/output signal. * 4 independent PI control advancement, 6 independent switch control advancement. * 1 analog output: May output DC 0~10V or 4~20 mA signal. * 1 floating point output: Outputs (24VAC) constitution by 2 groups relays. * 1 analog input: May accept the DC 0 ~ 5V, 0 ~ 10V or 4 ~ 20mA signal. * One of the internal temperature sensor,can be accept the external temperature sensor. * Many kinds of functions, to external input: automatic switch and remote control. * Can monitor all imports of high-and-low-limit, by setting the activation of alarm output. * May the temperature input and the setpoint transformation be the AO output. * Has the special-purpose control function of the humidity, the air blower, VAV, the setpoint cut and so on. * According to the sensor measuring range input signal linear will be transformed into a screen display value. * The user parameter and the control parameter establishment has the different password protection. * Blue backlight. * Luxurious version. * Power source protection and clock, 24 hours backups. * 16 time reversals compose 4 timetables. * Infrared remote control function. Product application:
* Air system: The constant temperature either changes the amount of wind air-conditioning system single-valve or the double control system choice. 1. May choose two level of heating establishments. 2. Supply air system air blast cascade control. 3. Humidity control. 4. Frequency control. * Air/aqueous system. Is suitable in 2 or 4 control system serpentined control: Humidity control,Is suitable in 2 or 4 control system serpentined control: Humidity control,Pressure control * Aqueous system: Radiator, floor heating or roof refrigeration. * Is suitable the control of the hotels¡¢ the conference rooms and so on the single room. |
|